MPPS SCANNING LEAKAGE SYSTEM FOR HEPA/ULPA FILTER
Operation Platform
MPPS(Most Penetratiable Particulate Size)
EN1822 is the most advanced, accurate and fast way to test HEPA or ULPA leaking
and it has been considered as Europe standard.
Method: Use MPPS method and DEHS vaporizing sealant to determine pressure
drop rate, media efficiency and leakage.
Application: HEPA (H11 ~H14) and ULPA (U15~U17).
Testing size: Maximum ≤1220mm (L), ≤1220 mm(W) & ≤300mm (D) |